Product Overview:
SPV Series automatic water supply equipment is rustic Cape Electrical Co., Ltd. Zibo three rich source of groundwater for the majority of rural and pastoral design series automatic water supply equipment. This series of water supply equipment using groundwater extraction wells with submersible pumps, water tower liquid level control with pressure tank or pressure control or automatic control mode constant frequency control clock automatic control of pump water to the user based on the user water situation. Optional pressure tank clean inside and outside temperature sintering special enamel anticorrosion tank, no rust, no scaling, no hang sediment, both Desanding function. Users can choose according to the water quality UV disinfection or chlorine dioxide disinfection of drinking water to improve health and safety.
Equipment conditions of use
Power supply voltage fluctuation: Three-phase four-wire 380V ± 10%; equipment Ambient temperature: -10 ℃ - +4 ℃ (not frozen);
Air relative humidity: ≤ 90% RH (non-condensing); places non-conductive dust and can corrode metal and damage the insulation of gas;
None of explosion; tilt: ≤ 5 ° place; shock: ≤ 0.6G
Function Description
1, SPV-B automatic water supply equipment water towers
1.1 The equipment to groundwater as a water source , the use of wells with submersible pumps for pumping groundwater to the water tower or high water tank to the user after the water supply, especially for small water users , there are towers or high water tank is easy to install roof construction sites .
1.2 The equipment level control with matching cabinet with manual and automatic functions. Manual status can be achieved by manually start and stop of the pump control ; automatic status by the level float switch or electrode type level switch is set according to the lower level when installing automatic start and stop pumps, ceiling level down , the lower the water level to boot. Control cabinet with a short circuit , phase , overload function with fault memory function, after a fault occurs, the fault should be excluded , and then continue to work only after manual reset .
1.3 disinfecting device according to the user selection of water quality , kill bacteria in the water, improve water quality water supply .
2, SPV-Y pressure tank pressure automatic water supply equipment
2.1 The equipment to groundwater as a water source , the use of groundwater wells with submersible pumps for pumping water into the pressure tank to the user , the system water pressure tank cushion . The equipment is especially suitable for large water users in water , the scene is not easy to build towers or high water tank in place .
2.2 The equipment supporting the use of pressure control cabinet with manual and automatic functions. Manual status can be achieved by manually start and stop of the pump control ; automatic status by the level float switch or electrode type level switch is set according to the lower level when installing automatic start and stop pumps, ceiling level down , the lower the water level to boot. Control cabinet with a short circuit , phase , overload function with fault memory function, after a fault occurs, the fault should be excluded , and then continue to work only after manual reset .
2.3 disinfecting device according to the user selection of water quality , kill bacteria in the water, improve water quality water supply .
3, SPV-H automatic frequency control water supply equipment
3.1 The equipment to groundwater as a water source , the use of wells with submersible pumps with frequency control groundwater pumping to the user directly to the water supply . The equipment is especially suitable for user needs 24 hours of water supply and large water changes , water quality requirements of the higher places . Equipment 24 -hour operation to the user constant pressure water supply, water users for a long time pump high speed, low speed pump water users came from , how much by smoke. If you need a small pump flow or sleep at night , you need to install the system pressure tank, pump sleep when meet water supply. The equipment energy-saving effect is obvious, pump soft start, soft stop , extended equipment life.
3.2 The equipment supporting the use of frequency control cabinet with a frequency inverter manual and automatic functions . Frequency of manual pump status achieved by manually start and stop controls for equipment installation and temporary emergency water situation ; inverter automatically adjust the pump speed automatic state constant pressure water supply to the user according to the set pressure sensor water pressure for long-term operation . Control cabinet with a short circuit , phase , overload function with fault memory function, after a fault occurs, the fault should be excluded , and then continue to work through before using the manual reset .
3.3 disinfecting device according to the user selection of water quality , kill bacteria in the water, improve water quality water supply .
Main performance parameters
No. | Model | Pump Model | The main performance parameters | Control equipment | ||||
Flowm3/h | Headm | Powerkw | SPV-B | SPV-Y | SPV-H | |||
1 | SPV-2-90-1.1 | 100QJ2-90 | 2 | 90 | 1.1 | QKG-1.1/B | QKG-1.1/Y | TPG-1.1 |
2 | SPV-2-132-1.5 | 100QJ2-132 | 2 | 132 | 1.5 | QKG-1.5/B | QKG-1.5/Y | TPG-1.5 |
3 | SPV-4-60-1.1 | 100QJ4-60 | 4 | 60 | 1.1 | QKG-1.1/B | QKG-1.1/Y | TPG-1.1 |
4 | SPV-4-80-1.5 | 100QJ4-80 | 4 | 80 | 1.5 | QKG-1.5/B | QKG-1.5/Y | TPG-1.5 |
5 | SPV-4-100-2.2 | 100QJ4-100 | 4 | 100 | 2.2 | QKG-2.2/B | QKG-2.2/Y | TPG-2.2 |
6 | SPV-6-51-1.5 | 100QJ6-51 | 6 | 51 | 1.5 | QKG-1.5/B | QKG-1.5/Y | TPG-1.5 |
7 | SPV-6-76-2.2 | 100QJ6-76 | 6 | 76 | 2.2 | QKG-2.2/B | QKG-2.2/Y | TPG-2.2 |
8 | SPV-6-110-3 | 100QJ6-110 | 6 | 110 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
9 | SPV-8-36-1.5 | 100QJ8-36 | 8 | 36 | 1.5 | QKG-1.5/B | QKG-1.5/Y | TPG-1.5 |
10 | SPV-8-55-2.2 | 100QJ8-35 | 8 | 55 | 2.2 | QKG-2.2/B | QKG-2.2/Y | TPG-2.2 |
11 | SPV-8-76-3 | 100QJ8-76 | 8 | 76 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
12 | SPV-8-89-3 | 100QJ8-89 | 8 | 89 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
13 | SPV-8-107-4 | 100QJ8-107 | 8 | 107 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
14 | SPV-10-25-1.5 | 100QJ10-25 | 10 | 25 | 1.5 | QKG-1.5/B | QKG-1.5/Y | TPG-1.5 |
15 | SPV-10-38-2.2 | 100QJ10-38 | 10 | 38 | 2.2 | QKG-2.2/B | QKG-2.2/Y | TPG-2.2 |
16 | SPV-10-53-3 | 100QJ10-53 | 10 | 53 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
17 | SPV-10-75-4 | 100QJ10-75 | 10 | 75 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
18 | SPV-10-105-5.5 | 100QJ10-102 | 5 | 102 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
19 | SPV-5-100-3 | 150QJ5-100 | 5 | 100 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
20 | SPV-5-150-4 | 150QJ5-150 | 5 | 150 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
21 | SPV-10-100-5.5 | 150QJ10-100 | 10 | 100 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
22 | SPV-10-150-7.5 | 150QJ10-150 | 10 | 150 | 7.5 | QKG-7.5/B | QKG-7.5/Y | TPG-7.5 |
23 | SPV-20-26-3 | 150QJ20-26 | 20 | 26 | 3 | QKG-3/B | QKG-3/Y | TPG-3 |
24 | SPV-20-39-4 | 150QJ20-39 | 20 | 39 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
25 | SPV-20-52-5.5 | 150QJ20-52 | 20 | 52 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
26 | SPV-20-78-7.5 | 150QJ20-78 | 20 | 78 | 7.5 | QKG-7.5/B | QKG-7.5/Y | TPG-7.5 |
27 | SPV-20-98-9.2 | 150QJ20-98 | 20 | 98 | 9.2 | QKG-9.2/B | QKG-9.2/Y | TPG-9.2 |
28 | SPV-20-111-11 | 150QJ20-111 | 20 | 111 | 11 | QKG-11/B | QKG-11/Y | TPG-11 |
29 | SPV-20-40-4 | 200QJ20-40 | 20 | 40 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
30 | SPV-20-54-5.5 | 200QJ20-54 | 20 | 54 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
31 | SPV-20-81-7.5 | 200QJ20-81 | 20 | 81 | 7.5 | QKG-7.5/B | QKG-7.5/Y | TPG-7.5 |
32 | SPV-20-93.9-9.2 | 200QJ20-93 | 20 | 93 | 9.2 | QKG-9.2/B | QKG-9.2/Y | TPG-9.2 |
33 | SPV-20-108-11 | 200QJ20-108 | 20 | 108 | 11 | QKG-11/B | QKG-11/Y | TPG-11 |
34 | SPV-32-26-4 | 200QJ32-26 | 32 | 26 | 4 | QKG-4/B | QKG-4/Y | TPG-4 |
35 | SPV-32-39-5.5 | 200QJ32-39 | 32 | 39 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
36 | SPV-32-52-7.5 | 200QJ32-52 | 32 | 52 | 7.5 | QKG-7.5/B | QKG-7.5/Y | TPG-7.5 |
37 | SPV-32-65-9.2 | 200QJ32-65 | 32 | 65 | 9.2 | QKG-9.2/B | QKG-9.2/Y | TPG-9.2 |
38 | SPV-32-78-11 | 200QJ32-78 | 32 | 78 | 11 | QKG-11/B | QKG-11/Y | TPG-11 |
39 | SPV-32-91-13 | 200QJ32-91 | 32 | 91 | 13 | QKG-13/B | QKG-13/Y | TPG-13 |
40 | SPV-32-104-15 | 200QJ32-104 | 32 | 104 | 15 | QKG-15/B | QKG-15/Y | TPG-15 |
41 | SPV-50-26-5.5 | 200QJ50-26 | 50 | 26 | 5.5 | QKG-5.5/B | QKG-5.5/Y | TPG-5.5 |
42 | SPV-50-39-9.2 | 200QJ50-39 | 50 | 39 | 9.2 | QKG-9.2/B | QKG-9.2/Y | TPG-9.2 |
43 | SPV-50-52-11 | 200QJ50-52 | 50 | 52 | 11 | QKG-11/B | QKG-11/Y | TPG-11 |
44 | SPV-50-65-15 | 200QJ50-65 | 50 | 65 | 15 | QKG-15/B | QKG-15/Y | TPG-15 |
45 | SPV-50-78-18.5 | 200QJ50-78 | 50 | 78 | 18.5 | QKG-18.5/B | QKG-18.5/Y | TPG-18.5 |
46 | SPV-50-91-22 | 200QJ50-91 | 50 | 91 | 22 | QKG-22/B | QKG-22/Y | TPG-22 |
47 | SPV-50-104-25 | 200QJ50-104 | 50 | 104 | 25 | QKG-25/B | QKG-25/Y | TPG-25 |
48 | SPV-80-22-7.5 | 200QJ50-22 | 80 | 22 | 7.5 | QKG-7.5/B | QKG-7.5/Y | TPG-7.5 |
Diameter | Volume(T) | Height(m) | Maximum Pressure |
φ500 | 0.27 | 1.5 | 0.6Mpa |
φ600 | 0.42 | 1.75 | 0.6Mpa |
φ700 | 0.6 | 1.8 | 0.6Mpa |
φ800 | 0.85 | 1.85 | 0.6Mpa |
φ1000 | 1.5 | 2.0 | 0.6Mpa |
φ1200 | 2.2 | 2.5 | 0.6Mpa |
UV disinfection device Technical Data
Model | Flowm3/h | Working PressureMpa | Fuse Specifications | Count | Parameters single UV lamp power W | Total power W |
LCW-Ⅱ-U(S)-2-1.0 | 2 | 1.0 | 1 | 1 | 30 | 30 |
LCW-Ⅱ-U(S)-5-1.0 | 5 | 1.0 | 1 | 1 | 55 | 55 |
LCW-Ⅱ-U(S/M)-8-1.0 | 8 | 1.0 | 2 | 3 | 30 | 90 |
LCW-Ⅱ-U(S/M)-12-1.0 | 12 | 1.0 | 2 | 2 | 55 | 110 |
LCW-Ⅱ-U(S/M)-15-1.0 | 15 | 1.0 | 2 | 4 | 30 | 120 |
LCW-Ⅱ-U(S/M)-20-1.0 | 20 | 1.0 | 2 | 3 | 55 | 165 |
LCW-Ⅱ-U(S/M)-32-1.0 | 32 | 1.0 | 3 | 4 | 55 | 220 |
LCW-Ⅱ-U(S/M)-45-1.0 | 45 | 1.0 | 5 | 5 | 55 | 275 |
LCW-Ⅱ-U(S)-60-1.0 | 60 | 1.0 | 5 | 6 | 55 | 330 |
LCW-Ⅱ-U(S)-90-1.0 | 90 | 1.0 | 5 | 5 | 75 | 385 |
Ordering
Category | Project | SPV-B | SPV-Y | SPV-H | Remark |
Equipment | Pump host | √ | √ | √ | |
Host Attachment | √ | √ | √ | 1 cabinet outside the control cable is not available within the range. | |
Pipes | √ | √ | √ | ||
Pressure tank | √ | √ | Optional | 2 control cabinet outside pressure, liquid level sensing instrument according order matching. | |
Control cabinet | √ | √ | √ | ||
Disinfection device | Optional | Optional | Optional | ||
Attachment | Check Valve | √ | √ | √ | 3 For ordering pipeline connection with the short tube, pipe, etc., please specify when ordering. |
Gate | √ | √ | √ | ||
Random | Instructions | √ | √ | √ | |
File | Certificate |
1, when ordering standard products only accurate to write product model, please read this manual carefully before selection to determine the technical performance, functional and structural aspects are configured to meet the needs.
2, accept the user a variety of options to select functions and configuration requirements. Be sure to indicate the specific requirements when ordering, and further confirm the scope of delivery, or be manufactured according to standard specifications.
2.1 The equipment can be changed to various types of ground wells centrifugal pumps with submersible pumps.
2.2 Material pressure tank can be equipped with ordinary steel or stainless steel according to user requirements.
2.3 accept other special features addition of water supply equipment.
3, the company's product design improvements have the right, subject to change without notice.