Description

lThe system provides accurate fault location solution for transmission and distribution power lines.

lThe fault distance Measurement error is less than ±150m irrelevant of line length, and free from influences of following factors, which affect fault location accuracy of traditional impedance measurement methods

nFault resistance

nVoltage and current transformer (TV,TA) errors

nInsufficient accuracy of line parameters due to neglecting of line transposing, distributed capacitance, etc. 

nUncertainty of zero sequence impedance due to variance of soil resistivity alone the line corridor

nLoad flow

lTraveling wave technique can be used to measure distance to fault in all kinds of power lines, including

nAC transmission lines

nHVDC transmission lines

nSeriously compensated transmission line

nLines with T branches

nThe line containing cable sections and overhead line

nMeasuring fault distance of a single phase to ground fault in non-effectively earthed distribution system.

lThe XC-2100E consists of the traveling wave data acquisition unit XC-100Einstalled at substations, the master station which runs traveling wave analysis software XCF-2100Edeployed in the control center and the communication network.

The whole system includes the following devices:

nXC-100E Traveling Wave Data Acquisition Unit

nXCF-2100E Master Station Software

For accurate timing for the devices involved, the XC-2100E also needs the GPS time synchronization module to provide accurate time reference.

 

XC-100E

 

XCF-2100E

 

Features:

lGPS synchronization is embedded into XC-100E

lAutomatic distance to fault calculation

lWide area fault location collects data from the whole power network

lLocation is performed directly on the network map

lUnlimited number of monitored lines

Specification:

XC-100E:

Analog Input:

lChannels: 3-24 configurable for 1-8 lines application.

lType of input:

nCurrent input with an clipped on CT

nCurrent input from CT

nVoltage input from PT

lAC Current input:

nNominal: 5A/1A

nBurden: < 0.4VA(In = 5A)< 0.2VA(In = 1A)

nOverload withstanding: 400%In, continuous. 4000% In, 1s.

lAC Voltage input:

nNominal: 57V/63.5V/69V

nBurden: < 0.4VA

nOverload withstanding: 200%Un, continuous. 250%Un, 10s.

Digital input:

5 Dry contacts(standard), can be extended to 16 contacts max.

Communication port:

1 Serial port, 2 Ethernet ports + 1 maintenance Ethernet port, 1 modem                     RJ-45 port, 1 USB port.

GPStime synchronization:

Internal GPS module time accuracy: 100ns

Display:

LCD display. Number of pixels: 256 x 64; dimensions: 132 x 39 mm

Memory space:

8GByte, 1000 records min.

Power supply:

85 to 264V, 50/60 Hz AC or 90 to 260V DC

Mechanical:

 Physical dimension:19", 2U

Weight: 4kg